Scope Rider RTH
Parameter:
<Channel>
Verwendung:
BUS:LIN:POLarity <Polarity>
Defines the idle state of the bus. The idle state is the recessive state and corresponds
to a logical 1.
Parameter:
<Polarity>
BUS:LIN:BITRate <CustomBitrate>
Sets the number of transmitted bits per second.
Parameter:
<CustomBitrate>
BUS:LIN:STANdard <Standard>
Selects the version of the LIN standard that is used in the DUT. The setting mainly defi-
nes the checksum version used during decoding.
Parameter:
<Standard>
BUS:LIN:DATA:THReshold <ThresholdValue>
Sets the threshold value for digitization of signals manually. If the signal value is higher
than the threshold, the signal state is high. Otherwise, the signal state is considered
low.
This value is only considered for
Benutzerhandbuch 1326.1578.03 ─ 19
C1 | C2 | C3 | C4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7
C3 and C4: only R&S RTH1004
Digital channels are available if option R&S RTH-B1 is installed.
*RST:
C1
Asynchroner Befehl
IDLLow | IDLHigh
IDLLow
The bus is idle (state = 1) when the signal is low
IDLHigh
The bus is idle (state = 1) when the signal is high
*RST:
IDLHigh
Bereich:
1000 bis 20000
Inkrement: 1
*RST:
9600
Std.-einheit: bps
V1X | V2X | J2602 | AUTO
*RST:
AUTO