BUS:UART:TECHnology <ThresholdType>
Sets the threshold value of the UART line as defined for various signal technologies.
Parameter:
<ThresholdType>
BUS:UART:THReshold <ThresholdValue>
Sets an individual threshold value for digitization of signals if
is set to USER.
Parameter:
<ThresholdValue>

BUS:SETReflevels

Sets the appropriate threshold or threshold for the selected serial protocol.
Verwendung:
BUS:UART:STDBitrate <Bitrate>
Sets the number of transmitted bits per second.
Parameter:
<Bitrate>
Benutzerhandbuch 1326.1578.03 ─ 19
TTL | ECL | CMOS | USER
TTL
1.4 V
ECL
-1.3 V
CMOS
2.5 V
USER
Set a user-defined value using BUS:UART:THReshold.
*RST:
TTL
Bereich:
-400 bis 400
Inkrement: 1E-3
*RST:
1.4
Std.-einheit: V
Ereignis
BPS_300 | BPS_600 | BPS_1200 | BPS_2400 | BPS_4800 |
BPS_9600 | BPS_14400 | BPS_19200 | BPS_28800 |
BPS_38400 | BPS_56000 | BPS_57600 | BPS_115200 |
BPS_128000 | BPS_230400 | BPS_460800 | BPS_921600 |
CUSTom
Values in bits per second.
CUSTom: Set the bit rate using BUS:UART:BITRate.
*RST:
BPS_14400
Fernsteuerbefehle