SPECtrum:CURSor<m>:SCPLing <State>
If enabled, the position of the cursor lines is adjusted if the vertical or horizontal scales
are changed. The cursor lines keep their relative position to the waveform.
If disabled, the cursor lines remain on their position on the display if the scaling is
changed.
Suffix:
<m>
Parameter:
<State>
SPECtrum:CURSor<m>:FREQuency[:VALue] <Frequency>
Queries the frequency at the specified cursor.
Suffix:
<m>
Parameter:
<Frequency>
SPECtrum:CURSor<m>:FREQuency:DELTa?
Queries the difference between the measured frequencies at both cursors.
Suffix:
<m>
Rückgabewerte:
<FrequencyDelta>
Verwendung:
SPECtrum:CURSor<m>:LEVel[:VALue]?
Queries the measured level at the specified cursor.
Suffix:
<m>
Benutzerhandbuch 1326.1578.03 ─ 19
.
1..2
ON | OFF
*RST:
ON
.
1..2
Bereich:
0 bis 500E+6
Inkrement: 10
*RST:
100E+6
Std.-einheit: Hz
.
1..2
irrelevant
Bereich:
-500E+6 bis 500E+6
Inkrement: 10
*RST:
300E+6
Std.-einheit: Hz
Nur Abfrage
.