R&S
Scope Rider RTH
METer:SENSe:VOLTage:AC:RANGe:AUTO <State>
METer:SENSe:VOLTage:DC:RANGe:AUTO <State>
Disables or enables the autoranging for the specified measurement.
The query always returns OFF or ON.
Parameter:
<State>
Beispiel:
15.7.2.4
AC+DC Strom- und Spannungsmessungen
METer<m>:SENSe:CURRent:AC:COUPling
METer<m>:SENSe:VOLTage:AC:COUPling
METer<m>:SENSe:CURRent:AC:COUPling <Coupling>
METer<m>:SENSe:VOLTage:AC:COUPling <Coupling>
Enables AC+DC measurements.
Suffix:
<m>
Parameter:
<CoupVoltageMeas> DCLimit | ACLimit
Benutzerhandbuch 1326.1578.03 ─ 19
OFF | ON | ONCE
OFF | ON
0 | 1 are not supported.
ONCE
Performs an immediate autorange and then turns off the autor-
anging.
METer:SENSe:VOLTage:DC:RANGe:AUTO ONCE
METer:SENSe:VOLTage:DC:RANGe:AUTO?
<-- OFF
..................................................................... 407
...................................................................... 407
.
1..4
R&S RTH1002: always 1, omit the suffix.
R&S RTH1004: Selects the voltmeter.
DCLimit
Enables AC+DC measurement.
ACLimit
Enables AC measurement.
*RST:
DCLimit
Fernsteuerbefehle
Digitalmultimeter (R&S RTH1002)
407