R&S
Scope Rider RTH
METer:SENSe:CAPacitance:NULL:STATe
METer:SENSe:CURRent:AC:NULL:STATe
METer:SENSe:CURRent:DC:NULL:STATe
METer:SENSe:RESistance:NULL:STATe
METer:SENSe:TEMPerature:NULL:STATe
METer:SENSe:VOLTage:AC:NULL:STATe
METer:SENSe:VOLTage:DC:NULL:STATe
METer<m>:SENSe:NULL:STATe
METer<m>:SENSe:RELative:STATe
METer:SENSe:CAPacitance:NULL:VALue
METer:SENSe:CURRent:AC:NULL:VALue
METer:SENSe:CURRent:DC:NULL:VALue
METer:SENSe:VOLTage:AC:NULL:VALue
METer:SENSe:VOLTage:DC:NULL:VALue
METer:SENSe:RESistance:NULL:VALue
METer:SENSe:TEMPerature:NULL:VALue
METer<m>:SENSe:NULL:VALU
METer:SENSe:CAPacitance:NULL:STATe <State>
METer:SENSe:CURRent:AC:NULL:STATe <State>
METer:SENSe:CURRent:DC:NULL:STATe <State>
METer:SENSe:RESistance:NULL:STATe <State>
METer:SENSe:TEMPerature:NULL:STATe <State>
METer:SENSe:VOLTage:AC:NULL:STATe <State>
METer:SENSe:VOLTage:DC:NULL:STATe <State>
Enables or disables the relative measurement. The reference value is defined using
the appropriate METer:SENSe:<function>:NULL:VALue command.
Parameter:
<State>
METer<m>:SENSe:NULL:STATe <SetRelative>
METer<m>:SENSe:RELative:STATe <SetRelative>
Enables or disables the relative measurement for the currently active measurement
type.
Relative measurements are not available for diode, continuity, and frequency measure-
ments.
Suffix:
<m>
Parameter:
<SetRelative>
Benutzerhandbuch 1326.1578.03 ─ 19
........................................................................ 409
........................................................................409
........................................................................409
.......................................................................... 409
........................................................................409
........................................................................ 409
........................................................................ 409
......................................................................................409
.................................................................................409
........................................................................ 410
........................................................................410
....................................................................... 410
........................................................................ 410
........................................................................ 410
.......................................................................... 410
........................................................................410
.......................................................................................411
OFF | ON
*RST:
OFF
.
1..4
R&S RTH1002: always 1, omit the suffix
R&S RTH1004: Selects the voltmeter.
ON | OFF
ON = 1, OFF = 0
*RST:
OFF
Fernsteuerbefehle
Digitalmultimeter (R&S RTH1002)
409