Herunterladen Diese Seite drucken

Trigger:can:crcerror; Trigger:can:data; Trigger:can:dcondition; Trigger:can:formerror - Rohde & Schwarz Scope Rider Rth Benutzerhandbuch

Handheld-oszilloskop
Vorschau ausblenden Andere Handbücher für Scope Rider RTH:
®
R&S
Scope Rider RTH
TRIGger:CAN:CRCerror <CrcError>
A CRC error occurs when the calculated result differs from the received value in the
CRC sequence.
Parameter:
<CrcError>
TRIGger:CAN:DATA <Pattern>
Specifies the data pattern to be found, in binary or hex format. Enter the pattern in
MSB first bit order.
Parameter:
<Pattern>
TRIGger:CAN:DCONdition <Relation>
Defines how the specified data pattern is compared with the acquired signal. The
instrument triggers if the acquired address is equal or unequal the defined pattern.
Parameter:
<Relation>
TRIGger:CAN:FORMerror <FormError>
A form error occurs when a fixed-form bit field contains one or more illegal bits.
Parameter:
<FormError>
TRIGger:CAN:FTYPe <FrameType>
CAN has several frame types which can be used as trigger condition.
For data and remote frames, the identifier format has to be set with
ITYPe.
Parameter:
<FrameType>
Benutzerhandbuch 1326.1578.03 ─ 19
ON | OFF
*RST:
ON
String that contains the pattern in binary format. The parameter
accepts the bit value X (don't care).
EQUal | NEQual
*RST:
EQUal
ON | OFF
*RST:
ON
ERRor | OVERload | DATA | REMote | DOR
ERRor
When a node recognizes an error, it cancels transmission by
sending an error frame.
The instrument triggers seven bit periods after the end of the
error flag that is marked by a dominant-recessive edge.