• The supply cord cannot be replaced. If the cord is damaged, the
appliance should be scrapped.
To keep water clean
• Periodically change water to prevent water from becoming sticky and
forming microorganisms.
Trouble Shooting
If the pump fails to run, the following should be checked:
• Check the circuit breaker, or try a different outlet to make sure that the
pump is getting electrical power. NOTE-Always disconnect the pump from
electrical outlet before checking.
• Check the pump discharge and tubing for kinks and obstructions.
• Algae buildup can be flushed out with a garden hose.
• Remove the pump filtering cover & pump chamber to access the impeller
area. Turn the rotor to ensure it is not broken or jammed.
With little flow rate, the pump will spew or "burp":
• Check the water level to make sure the pump is completely
submerged.
If abnormal noise is heard during operation (with water):
• First disconnect the power supply and then remove pump filtering cover &
pump chamber.
• Use hand to grip the impeller, gently pull the impeller/rotor assembly out
of the pump housing.
• Rinse the impeller/rotor assembly and the cavity with clean water. If
breakage or surface damage is found on the assembly, contact your
distributor for part replacement.
Warning Ill
The water pump must be fully soaked or it will be damaged!
Minimum Water Leverl (Niveaude I'eau minimum)
- 11 -