Herunterladen Diese Seite drucken

REMS Multi-Push S Betriebsanleitung Seite 21

Vorschau ausblenden Andere Handbücher für Multi-Push S:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
eng
REMS V-Jet H, cleaning and preservation unit
Printer
Paper roll, pack of 5
Case with inserts for printer
REMS Peroxi Color, dosing solution for disinfection
REMS CleanH, cleaner for heating systems
REMS NoCor, corrosion protection for heating systems
Test strips 0 – 1000 mg/l H
O
2
2,
Test strips 0 – 50 mg/l H
O
pack of 100
2
2,
Suction/pressure hose Ø 1", 1.5 m long, with 1" hose screw fittings, 
for flushing, disinfection, cleaning, preservation 
High-pressure hose Ø ½", 1.5 m long, with ½" hose screw fittings, 
for pressure testing with water (REMS Multi-Push SLW)
Pneumatic hose Ø 8 mm, 1.5 m long, with quick couplings NW 5
Connecting hose compressor/water connections with 1" hose
screw fitting and quick coupling NW 7.2 for pressure testing 
with air (REMS Multi-Push SL/SLW)
Compressed air hose pneumatic tools, 1.5 m long,
with quick couplings NW 7.2, for connecting pneumatic tools
Compressed air hose Ø 8 mm, 7 m long, with quick coupling
DN 5 (plug) and G ½" hose screw fitting, for pressure testing 
with compressed air (REMS Multi-Push SL/SLW)
Compressed air hose Ø 8 mm, 1.5 m long, with quick coupling
DN 5 (plug, socket) for gas testing with compressed air
(REMS Multi-Push SL/SLW)
High-pressure hose Ø ½", 7 m long, with G ½" hose screw fittings, 
with caps, for pressure testing of pipe systems and vessels
with water (REMS Multi-Push SLW)
1" double nipple, for connecting 2 suction/pressure hoses
Fine filter with filter cartridge 90 µm 
Fine filter cartridge 90 µm 
Caps 1" with chain (REMS Multi-Push)
Plugs 1" with chain (suction/pressure hoses)
Plugs ½" with chain (REMS Multi-Push SL/SLW)
Caps ½" with chain (high-pressure hose)
Pressure gauge 6 MPa/60 bar /870 psi
Fine scaled pressure gauge 1.6 MPa/16 bar/232 psi,
Fine scaled pressure gauge 250 hPa/250 mbar/3.6 psi,
Hood
XL-Boxx system case for hoses
1.3 Applications
Device storage temperature 
Water temperature 
Ambient temperature 
pH value
Smallest test volume
Compressor
Operating pressure 
Oil separation rate
Extraction rate 
Compressed air vessel volume (Fig. 1 (35))
Condensation and particle filter  
Flushing of pipe systems
Flushing water connections
Water pressure pipe network 
Water pressure when flushing with compressed air  ≤ 0.7 MPa/7 bar/101 psi
Water flow rate 
Pipe diameter installation 
Pressure testing of drinking water installations (REMS Multi-Push SL/SLW)
Pressure test with compressed air 
Reading accuracy < 200 mbar
Reading accuracy ≥ 200 mbar 
Pressure test with water 
Reading accuracy
Pressure testing of gas installations (REMS Multi-Push SL/SLW)
Pressure test with compressed air 
Reading accuracy < 200 mbar
Reading accuracy ≥ 200 mbar 
1.4 Electrical/electronic data
Type of protection terminal box
Type of protection device, motor
Protection class
Operating mode (continuous operation)
Screen (LCD)
Resolution
Data transfer with USB stick
Printer, battery
Charger printer
1.5 Dimensions L × W × H
Paper roll printer B × Ø  
pack of 100
≥ 5°C (≥ 41 °F)
5°C – 35°C (41 °F – 95 °F)
5°C – 40°C (41 °F – 104 °F)
approx. 10 l
≤ 0.8 MPa/8 bar/116 psi
≤ 230 Nl/min
≤ 1 MPa/10 bar/145 psi
≤ DN 50, 2"
≤ 0.4 MPa/4 bar/58 psi
1 hPa/1 mbar/0.015 psi
100 hPa/0,1 bar/1.5 psi
≤ 1.8 MPa/18 ba r/261 psi
0.02 MPa/0.2 bar/3 psi
≤ 0.3 MPa/3 bar/44 psi
10 Pa/0,1 mbar/0.002 psi
100 hPa/0,1 bar/1.5 psi
230 V~; 50 Hz; 1,500 W
110 V~; 50 Hz; 1,500 W
128 × 64 pixels
NiMH 6 V – ---; 800 mAh
Input
100 – 240 V~; 50 – 60 Hz; 0.15 A
5 V – ---; 680 mA
Output
570 × 370 × 530 mm (22.4" × 14.6" × 20.9")
57 × ≤ 33 mm
115612
1.6 Weight
115604
REMS Multi-Push S
090015
REMS Multi-Push SL
115703
REMS Multi-Push SLW
115605
1.7 Noise information
115607
Work place-related
115608
Emission value
091072
091073
2 Start-up
115633
CAUTION
CAUTION
Transport weights above 35 kg must be carried by at least 2 persons.
115634
115637
Compressed air line compressor/pressure vessel (47) gets hot and can cause
burns if touched.
NOTICE
NOTICE
115618
REMS Multi-Push is not intended/suitable for permanent connection to the
115621
installation. Disconnect all hoses from the installation after completing the work.
REMS Multi-Push may not be operated unattended.
2.1 Electrical connection
115667
WARNING
WARNING
Caution: Mains voltage present! Before connecting the electronic flushing 
115747
and pressure testing unit, check whether the voltage given on the rating plate
corresponds to the mains voltage. Only use sockets/extension leads with a
functioning PE contact.
115661
Check the function of the PRCD fault current circuit breaker
045159
The function of the PRCD fault current circuit breaker (Fig. 1 (1)) must be
115609
checked every time before start-up and before beginning work:
043054
115619
1. Plug the mains plug into the socket.
115620
2. Press the RESET button (2), the PRCD control lamp (Fig. 1 (39)) lights red
115624
(operating state).
115623
3. Pull out the mains plug, the PRCD control lamp (39) must go out.
115140
4. Plug the mains plug back into the socket.
115045
5. Press the RESET button (2), the PRCD control lamp (39) lights red (oper-
047069
ating state).
115677
6. Press the TEST button (3), the PRCD control lamp (39) must go out.
579600
7. Press the RESET button (2) again, the PRCD control lamp (39) lights red.
The control lamp (Fig. 2 (5)) lights green. REMS Multi-Push is ready for
operation after about 10 s.
WARNING
WARNING
If the described functions of the PRCD fault current circuit breaker (Fig. 1 (1))
6,5 – 9,5
are not fulfilled, the device may not be used. There is a danger of electric shock. 
The PRCD fault current circuit breaker tests the connected device, not the
installation before the socket nor interconnected extension leads or cable reels.
On building sites, in a wet environment, indoors and outdoors or under similar
oil-free
installation conditions, only operate the electronic flushing and pressure testing 
unit on the mains with a fault current protection switch (FI switch) which interrupts
4.9 l
the power supply as soon as the leakage current to earth exceeds 30 mA for
5 µm
200 ms. A cable cross-section that corresponds to the power of the electronic
flushing and pressure testing unit must be selected when using an extension lead. 
DN 25, 1"
2.2 Menu structure and on-screen displays
Press the On/Off button on the input and control unit's operating panel (Fig. 2
(4)) for approx. 2 s, then release it. REMS Multi-Push is switched on and the
≤ 5 m³/h
compressor switches on. The screen (6) is illuminated and the Logo REMS
Multi-Push logo appears followed by the Start menu:
REMS Multi-Push S:
Flushing
Ingredients
Memory Manager
The screen display contains a maximum 5 lines with 20 characters each. Lines
with defaults or test values are displayed language-independently with phys-
ical formula symbols, a uniform verbal abbreviation and the value of the test
criterion in the sub-routines. These have the following meanings:
p refer
bar xxx
IP 44
p refer
mbar xxx
IP 20
p actual bar xxx
I
p actual mbar xxx
S 1
p diff
bar xxx
3.0"
p diff
mbar xxx
t stabi
min xxx
USB port
t test
min xxx
Δ > 10K   
PfS 
P+M
p H
O
bar
2
v H
O 
m/s 
2
t H
O 
min 
2
L
= 73 dB(A); L
= 92 dB(A); K = ± 1 dB(A)
PA
WA
REMS Multi-Push SL/SLW:
Flushing
Ingredients
Testing
Compressed Air Pump
Memory Manager
reference test pressure bar
reference test pressure mbar
actual test pressure
bar
actual test pressure
mbar
differential test pressure bar
differential test pressure mbar
stabilisation/wait time
min
test time
min
difference >10°C (10 Kelvin) water/environment
press fitting system (ZVSHK)
load test plastic + metal
water pressure
minimum flow speed
flushing/disinfecting/cleaning/preservation time
eng
32.0 kg (71 lb)
36.7 kg (81 lb)
39.0 kg (86 lb)