OPC UA (continued)
9.3
Connection established via OPC UA with
UaExpert
There are several OPC-UA clients to connect to the
OPC-UA server of the BIS U-6127 processor unit. In this
user's guide, the connection setup using the UaExpert
from Unified Automation is shown as an example. The
OPC-UA client UaExpert is available for download free of
charge from the Unified Automation homepage
(www.unified-automation.com) and must be installed on
the PC.
The connection between OPC-UA client and OPC-UA
server (BIS U-6127) can be established via an unsecure
(see chapter 9.3.1) or secure variant (see chapter 9.3.2 on
page 136).
9.3.1
Unsecure connection setup between PC
(OPC-UA client) and the BIS U-6127 device
(OPC-UA server)
Connect the PC (OPC-UA client) to the BIS U-6127
device (OPC-UA server):
1. Launch the UaExpert application.
2. Add a new server.
Fig. 9-4:
Server Dialog
3. Switch to the a
tab.
dvanced
4. Assign a c
onfiguRation name
RFID Provider).
5. Enter the following e
ndpoint
opc.tcp://192.168.10.2:4840
The IP address 192.168.10.2 is fixed in the
delivery state. The IP address can be changed
via the web server, the 007 protocol or the UHF
Manager.
Fig. 9-5:
OPC-UA-Add-Server
www.balluff.com
(e.g. Balluff BIS U-6127
uRl:
6. Depending on the settings in the device (web server),
the security settings of S
ecuRity policy
must be changed (see chapter 9.2 on
SecuRity mode
page 133). For an unsecure connection, enter n
and n
in both fields.
one
If the S
ecuRity policy
m
eSSage SecuRity mode
Fig. 9-5), a connection between server and
client can be established in any case in the
delivery state, but the connection is unsecure
(no endpoint identity and no encryption). If only
secure connections are to be used, unsecure
connections must be blocked on the device
side.
7. Right-click on the server and select c
to the server.
Fig. 9-6:
Connection setup
⇒ The OPC-UA client (PC) is connected to the
OPC-UA server (BIS U-6127). This is also visible by
the server icon.
Fig. 9-7:
Server connected to client
In addition, the complete structure is displayed in the
a
window (see Fig. 9-17).
ddReSS Space
and m
eSSage
one
is set to n
and the
one
is set to n
(see
one
to connect
onnect
english
135