Processor unit
7
Startup and operation (continued)
Initial Q-value/expected number of tags
Parameter-ID:
0x0002
hex
UHF-Manager:
Menu:
Device settings > Parameters...> Basic
UHF (expected number of tags)
and
Devices settings > Advanced
Parameters... > Air interface (Q-value)
OPC UA:
Webserver:
Menu: Configuration > RFID > UHF
extended
The Q-value is used as a key figure for the number of data
carriers expected in the detection range of the antenna.
The Q-value can be used to optimize the time taken for
data carrier detection. In addition, the detection rate can
decrease if the Q-value is selected too high.
The set Q-value is only used as a starting value during
detection and can be optimized by the processor unit.
The following table shows a recommendation for setting
the Q-value, depending on the expected number of data
carriers:
Expected number of
data carriers (approx.)
1
2
5
10
25
50
100
200
500
Adjustable values for the Q-value:
Length
Permissible
Factory
[bits]
values
setting
8
1...15
4 (Q-value = 4)
Setting fields that specify the expected number of tags are
always rounded to a number calculated from the Q-value.
www.balluff.com
Recommended Q-value
1
2
3
4
5
6
7
8
9
Meaning
Number of
expected
data carriers
Session (Inventoried Flag)
Parameter-ID:
0x0005
hex
UHF-Manager:
Menu: Device Settings > Advanced
parameters... > Air interface
OPC UA:
Webserver:
Menu: Configuration > RFID > UHF
extended
EPCglobal
Class-1 Generation-2 data carriers support
TM
session flags to indicate whether a data carrier has already
been detected. This is done via the status of the session
flags (
/
). In this way, it is possible to
detected
not detected
control whether and when a data carrier that has already
been detected can be detected again. Different rules apply
to the 4 sessions (0...3) with regard to the transition from
the Detected status back to the u
Adjustable values:
Length
Permissible
Factory setting Meaning
[bits]
values
8
0: Session 0
0
1: Session 1
2: Session 2
3: Session 3
Changing the session is reserved for experts
and is only recommended if the default setting
does not provide satisfactory results. Detailed
information on the
SeSSion
the standard according to EPCglobal
Generation-2.
status.
ndetected
Session 0
flag can be found in
Class-1
TM
english