Startup and operation (continued)

Program settings

l
anguage
Switch menu language between German/English.
c
hange uSeR level
This menu item has been replaced by the Login area
on the BIS U-6127 and is used only for compatibility
with other processor units.
i
...
nteRface
Opens the window for the interface settings for
RS232 / TCP/IP.
Device settings
S
leep mode
Is not available when using the BIS U processor unit.
R
(F5 key)
eSet SyStem
Causes the BIS U processor unit to perform a restart.
A previous login with administrator rights is required.
d
/c
(F8 key)
iSconnect
onnect
Opens or closes the last used connection.
p
...
aRameteRS
Opens the parameter window.
a
...
dvanced paRameteRS
Opens the window for advanced parameters (area is
password protected, see menu item Change user level
on page 30).
S
yStem Setup
Area is only accessible to Balluff service staff.
d
evice type
Shows a list of supported devices and allows manual
selection. Depending on the selected device, the user
interface changes.
This function is only intended for offline mode.
The
device type
the connection is established.
Help
v
(F1 key)
iew help
Opens the help function for the configuration software
v
uhf m
(Ctrl + I key)
ia
anageR
Opens the window for user information
– Software version of the configuration software
– Contact details of Balluff GmbH
Finish
Closes the configuration software.
30
english
is selected automatically when
7.1.3

Interface settings

The
allow the BIS U processor unit to be
inteRface SettingS
connected to a Windows
PC via a TCP/IP connection.
TM
A service port (USB) is also available for maintenance or
service functions, which can be connected via a virtual
COM port.
TCP/IP connection
Open a TCP/IP connection:
1. Menu: Program settings > Interface...
⇒ The Interface Settings window opens.
2. Select the TCP/IP tab.
Fig. 7-3:
Interface settings
3. Select the network adapter in the n
pull-down menu.
4. Click the BiS S
button.
eaRch
⇒ BIS U processor units are searched for and listed in
the table.
5. Select BIS U processor unit by clicking on the
corresponding line.
6. c
/d
establishes or disconnects the
onnect
iSconnect
TCP/IP connection.
In the a
ip
area, a new IP address or a
SSign new
addReSS
new default gateway can be assigned to the device
connected via TCP/IP or USB. Via the checkbox u
dhcp, the device can be switched to DHCP to
automatically obtain an IP address.
DHCP can only be used in a network that
allows the dynamic assignment of IP addresses.
This must be ensured before activating DHCP,
otherwise it may no longer be possible to
access the processor unit via the network. In an
emergency, this setting can be reversed via the
service port (USB). An M12-USB service cable
is required for this (see chapter 10.3 on
page 173).