Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS U-6127-081-1 4-06-ST36 Betriebsanleitung Seite 294

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-6127-081-1_4-06-ST36
Processor unit
8
007 protocol (continued)
If the status report cannot be generated, a negative status
message follows.
Byte
Length
Command
element
00
1
Status
01
1
Status code
The positive status message is acknowledged with <ACK>
or <EOT> and contains status information about the
successfully written data. If several status packets are
ready, they are acknowledged with <ACK>, the last packet
to be transmitted with <EOT>.
Byte
Length
Command
element
00
1
Status
01...03 3
Number of
packets contai-
ning status
information
04...06 3
Current packet
number
07...12 6
Number of bytes
in the data block
13...
No. of
Data block
bytes
Last
1
BCC
byte
Data block
The data block contains a list of the data carriers (EPCs)
that were successfully written.
Byte
Length
Command
element
00
64
EPC Tag 1
65
64
EPC Tag 2
(optional)
...
...
EPC Tag n (optio-
nal)
With <STX>, further status packets can be requested, if
available. The last available status packet is acknowledged
with <EOT> and contains the status data of the last
packet.
Byte
Length
Command
element
00
1
Status
118
english
Command identifier 'k': Kill
Permanently disables a selected data carrier and locks it to
prevent any use.
Value range
To execute the
be set and written to the data carrier.
<NAK>
The password has a length of 4 bytes and is transmitted
as a string with 8 bytes in ASCII hex number format.
See table Status
codes on page
Example of password (MSB...LSB):
94
Value range
<ACK> or
Byte
<EOT>
"000"..."999"
00
01
"000"..."999"
"000000"...
02
"999999"
Byte:
10
00
...FF
hex
hex
00
...FF
hex
hex
Status message:
Byte
00
Value range
01
Byte:
If the status message is positive, the
00
...FF
hex
hex
confirmed with <STX>.
Byte:
00
...FF
Byte
hex
hex
Byte:
00
...FF
00
hex
hex
Status message:
Byte
00
Value range
01
<STX>
command, a
kill
kill
in hex format: 010A8FCC
hex
in ASCII-hex-format: "010A8FCC"
A kill command permanently disables the
selected data carrier and cannot be
undone!
Details on password protection and locking and
unlocking (l
) of UHF RFID data carriers can
ock
be found in the EPC
Radio-Frequency Identity
TM
Protocols Generation-2 UHF RFID standard.
Length
Command
element
1
Command
identifier (ASCII)
1
Antenna number
(ASCII)
8
Password (ASCII
hex) (MSB...LSB)
1
BCC
Length
Command
element
1
Status
1
Status code
Length
Command
element
1
Status
Length
Command
element
1
Status
1
Status code
password must first
Value range
'k'
'0': All active
antennas
'1'...'4': Single
antenna
"00000000"...
"FFFFFFFF"
00
...FF
hex
hex
Value range
<ACK> or
<NAK>
See Status codes
on page 94
command can be
kill
Value range
<STX>
Value range
<ACK> or
<NAK>
See Status codes
on page 94

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für: