BIS U-6127-081-1_4-06-ST36
Processor unit
8
007 protocol (continued)
Command identifier 'E': Change device parameters
Writing general and antenna-related parameters. Antenna-
related parameters can be set individually for each
antenna. For a detailed parameter description, see
chapter 7.3 on page 49.
Byte
Length
Command
element
00
1
Command
identifier (ASCII)
01
1
Antenna number
(ASCII)
02...03 2
Number of bytes
(ASCII)
04...07 4
Parameter
number (ASCII
hex)
08
1
Data
...
...
...
Last
1
BCC
byte
Status message:
Byte
Length
Command
element
00
1
Status
01
1
Status code
02
1
BCC
98
english
Command identifier 'V': Read version
Reads out the firmware version string of the processor unit
used.
Byte
Value range
00
'E'
01
'0': All antennas/
If the command is executed successfully, data follows.
General
Byte
'1': Antenna 1
'2': Antenna 2
00
'3': Antenna 3
'4': Antenna 4
"00"..."99"
Last
byte
"0000"..."FFFF"
If the data cannot be provided, a negative status message
follows.
Byte
00
...FF
hex
hex
00
...FF
hex
hex
00
00
...FF
hex
hex
01
02
Value range
<NAK>
See table Status
codes on page
94
00
...FF
hex
hex
Length
Command
element
1
Command
identifier (ASCII)
1
BCC
Length
Command
element
Variable
Version string
1
BCC
Length
Command
element
1
Status
1
Status code
1
BCC
Value range
'V'
00
...FF
hex
hex
Value range
ASCII string with
variable length
00
...FF
hex
hex
Value range
<NAK>
See table Status
codes on page
94
00
...FF
hex
hex