Sign tag data

When data is signed on data carriers, additional data is
added to the actual data (TID, EPC, user data) with the
help of a secret key and a calculation algorithm, which is
later used to verify the authenticity of the data.
A 224-bit secret (private) key and an elliptic curve algorithm
are used, which offers a high level of security.
When reading the data carriers, the data is accepted as
valid only if the following conditions are met:
1. There is a signature.
2. The signature with the correct secret key of the
operator was generated.
3. Neither data nor signature were changed afterwards.
UHF data carriers (tags) with at least 64 bytes of memory
available in the user area that do not have to be used for
application data can use the tag signature. The f
/
commands must be used for this. Here, the first
Read
wRite
64 bytes of the user area are provided with a signature that
usually includes the EPC and the TID of the tag as well as
a secret key and can only be generated by devices that
have the same secret key.
The key must be generated and programmed into the
device by the person setting it up (see chapter 7.3.6 on
page 82). The key should be stored securely and
protected against unauthorized access. In the device itself,
the key is stored securely in the Secure Element.
In order to sign tag data or verify the signature,
the customer must import their own private key
into the Secure Element of the device. To import
a key, a special license must be purchased from
Balluff Sales: The key update ticket.
12
english
3.8

Display elements

oRmatted
Fig. 3-3:
Display elements
BIS U status
LED
RF active
Tag present Off
Power/
status
User
Ant1...Ant4 Off
Color
Meaning
Off
Antennas Ant1...Ant4 inactive
Blue
Active communication via one
of the antennas Ant1...Ant4
No data carriers in the detection
range of Ant1...Ant4
Yellow
Min. 1 data carrier detected in
(3 s)
the detection range
Off
No supply voltage
Red
Not ready for operation (see
chapter 7.4 on page 85)
Yellow
When switching on: Supply
voltage present
During operation: Warning
status present (see chapter 7.4
on page 85)
Green
Operational
Green
Boot mode
flashing
(1 s)
Off,
Freely programmable via
Red,
OPC UA
Yellow,
Green
Antenna port inactive
Yellow
Antenna port active

Werbung