Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS U-6127-081-1 4-06-ST36 Betriebsanleitung Seite 272

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-6127-081-1_4-06-ST36
Processor unit
8
007 protocol (continued)
Command identifier 'j': Change network parameters
Set the Ethernet network parameters. The parameters are
transferred in ASCII-hex number format.
IP address:
192.168.68.101
Subnet mask:
255.255.255.0
Byte
Length
Command
element
00
1
Command
identifier (ASCII)
01...08 8
IP address (ASCII
hex)
09...16 8
Subnet mask
(ASCII hex)
17...24 8
Gateway address
(ASCII hex)
25
1
IP configuration
(ASCII)
26
1
BCC
Status message:
Byte
Length
Command
element
00
1
Status
01
1
Status code
If the status message is positive, a system reboot is
initiated with <STX> in order to adopt the new network
parameters.
Byte
Length
Command
element
00
1
Control com-
mand
The execution of this command requires prior login with a
user with admin privileges.
96
english
Command identifier 'o': Read transmitting power
Readout of the currently set transmitting power (ERP/EIRP)
as ¼-dBm value.
Example:
"C0A84465"
When reading out the transmitting power, the following
"FFFFFF00"
values are returned (5c
Value range
5C
'j'
hex
92 × ¼ dBm = 23 dBm
A transmitting power of 23 dBm is thus set.
"00000000"...
Byte
"FFFFFFFF"
"00000000"...
00
"FFFFFFFF"
"00000000"...
01
"FFFFFFFF"
'0': Static
02
'1': DHCP
00
...FF
hex
hex
Status message
Byte
Value range
00
<ACK> or
<NAK>
01
See table Status
codes on page
94
If the status message is positive, data is requested with
<STX>.
Byte
Value range
00
<STX>
If the command is executed successfully, data follows.
Byte
00
01...02 2
03
If the data cannot be provided, a negative status message
follows.
Byte
00
01
):
hex
Transmitting power High byte: '5'
Transmitting power Low byte: 'c'
= 92
Length
Command
element
1
Command
identifier (ASCII)
1
Antenna number
(ASCII)
1
BCC
Length
Command
element
1
Status
1
Status code
Length
Command
element
1
Control com-
mand
Length
Command
element
1
Status
Transmitting
power (ASCII
hex)
1
BCC
Length
Command
element
1
Status
1
Status code
Value range
'o'
'1'...'4': Single
antenna
00
...FF
hex
hex
Value range
<ACK> or
<NAK>
See table Status
codes on page
94
Value range
<STX>
Value range
<ACK>
"00"..."FF"
00
...FF
hex
hex
Value range
<NAK>
See table Status
codes on page
94