Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS U-6127-081-1 4-06-ST36 Betriebsanleitung Seite 269

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-6127-081-1_4-06-ST36
Processor unit
8
007 protocol (continued)
Universal data carrier (formatted tag data)
Function
Command
recognition
ASCII
Detect data
'-' 'L'
2D4C
carrier, univer-
sal
Read data
'-' 'R'
2D52
carrier, univer-
sal
Write data
'-' 'W'
2D57
carrier, univer-
sal
www.balluff.com
Description
HEX
Detects the data
hex
carriers that are in
the detection range
of the specified
antenna and
returns a list with
individually para-
meterizable data.
Read individually
hex
parameterizable
data from a data
carrier.
Write individually
hex
parameterizable
data to a data
carrier.
IO-Link
Function
Command
recognition
ASCII
Acyclical
'i'
demand data,
read
Acyclical
'e'
demand data,
write
Digital output
'/'
ports, set/
reset
Digital input
'*'
ports, read
Cyclical
'Y'
process data,
read
Cyclical
'X'
process data,
write
IO-Link master
'#'
configuration,
read
IO-Link master
'g'
configuration,
write
Description
HEX
69
Receive demand/
hex
parameter data
from IO-Link
device.
65
Send demand/
hex
parameter data to
IO-Link device.
2F
Set/reset pin 2 or
hex
pin 4 if used as
digital output.
2A
Query states of
hex
pin 2 or pin 4, if
these are operated
as digital inputs.
Read cyclical
59
hex
IO-Link process
data.
58
Write cyclical
hex
IO-Link process
data.
23
Read out the
hex
IO-Link master
configuration.
67
Set the IO-Link
hex
master configura-
tion.
english
93