Herunterladen Inhalt Inhalt Diese Seite drucken

Rfidlockoperationenumeration; 9.7.10 Rfidlockregionenumeration; 9.7.11 Rfidpasswordtypeenumeration; 9.7.12 Rfidscanresult - Balluff BIS U-6127-081-1 4-06-ST36 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-6127-081-1_4-06-ST36
Processor unit
9
OPC UA (continued)
9.7.9

RfidLockOperationEnumeration

This data type defines the action to be executed in the
Lock command. The following values are defined and
allowed. The exact effect of the respective action depends
on the selected memory area of the tag.
A more detailed description can be found in the standards
according to EPCglobal
Class1 Generation2 and
TM
OPC UA AutoID Companion Specification 1.0.
Value
Description
Passwords
Lock_0
Write and read
commands to the
password are only
possible with a
valid access
password.
Unlock_1
Write and read
commands to the
password are
possible without
knowing the
access password.
Permanent-
Write and read
Lock_2
commands to the
password are no
longer possible at
all. The operation
is not reversible.
PermanentUn-
Read and write
lock_3
commands to the
password are
possible, but the
area can no longer
be locked.

9.7.10 RfidLockRegionEnumeration

This data type defines the memory area to be locked with
the LockTag() method (see page 147). The following
values are defined:
Value
Description
Kill_0
Kill password
Access_1
Access password
EPC_2
UID/EPC bank (bank 01)
TID_3
TID bank (bank 10)
User_4
User memory bank (bank 11)
www.balluff.com

9.7.11 RfidPasswordTypeEnumeration

This data type specifies which password should be
changed (method: SetTagPassword() see
chapter SetTagPassword on page 155). The following
values are defined:
Value
Access_0
Kill_1
Read_2
Memory bank
Write_3
It can be read
without a pass-
The Read_2 and Write_2 values are defined but not
word, but written
permitted. They are not implemented in the standard
only with a valid
according to EPCglobal
access password.
Both the read and

9.7.12 RfidScanResult

write operation
This structure returns the data of a detected tag and
can be performed
additional information in the array of type Sightings.
without a pass-
It is structured as follows.
word.
Name
It can be read
RfidScanResult
without a pass-
CodeType
word, but written
only with a valid
access password.
The operation is
not reversible.

ScanData

Both the write and
read operation can
be performed
Timestamp
without a pass-
Location
word. However,
the area can no
longer be locked.
Sightings
Description
Access password
Kill password
Read password
Write password
Class-1 Gen-2 V1.
TM
Data Type
Description
Structure
CodeTypeData-
Specifies the format
Type (see
in which the scan-
page 162)
ned data should be
output under Scan-
Data.
ScanData
Data of the success-
fully scanned tag.
UtcTime
UtcTime on read.
Location
Returns the location
where the tag was
detected.

RfidSighting[]

Information about
(see page 164)
each read of the tag
on an antenna:
1: Number of the
antenna
2: RSSI value
3: UtcTime at read
4: Transmitting
power used during
read