Processor unit
9
OPC UA (continued)
SetFilter
This method can be used to set a filter for certain parts of
the EPC and the TID. Furthermore, the minimum and
maximum values of the RSSI to be achieved and the EPC
length can be set.
In synchronous scanning mode, only the data carriers
whose data match the settings of the filter are displayed
after the filter is activated. An example of the application
can be found on page 226.
Min. Access Level: Expert
Default value: The default value is set via the device
parameterization (see chapter 7.3 on page 49).
Call parameter
Name
Data Type
FilterIndex
UInt16
FilterOperation
BalluffFilterOpe-
rationEnumera-
tion (see chap-
ter 9.7.3 on
page 162)
EpcDataFilter
BalluffFilterDa-
taBlock
TidDataFilter
BalluffFilterDa-
taBlock
MinRSSI
Int16
MaxRSSI
Int16
150
english
Description
Index of the newly
created filter.
Operation with
which the filter is to
be applied to the
Return parameter
data. Currently only
AND is supported.
EPC filter setting:
From which
address, on how
many bits and with
which data the filter
should be applied.
These filter specifi-
cations refer only to
the EPCs of the
tags.
TID filter setting:
From which
address, on how
many bits and with
which data the filter
should be applied.
These filter specifi-
cations refer only to
the TIDs of the tags.
Minimum RSSI value
with which a tag
must be detected.
Value range: −128...
+127
Default value: −128
(no filtering)
Maximum RSSI
value with which a
tag may be
detected.
Value range: −128...
+127
Default: +127 (no
filtering)
Name
Data Type
MinEpcLength
UInt16
MaxEpcLength
UInt16
UseAsDefault
Boolean
Name
Data Type
Result
AutoIdOperati-
onStatusEnu-
meration (see
chapter 9.7.2
on page 161)
Description
Minimum EPC
length of a tag in
bytes.
Value range 0...62
Default: 0 (no filte-
ring)
Maximum EPC
length of a tag in
bytes.
Value range 0...62
Default: 62 (no
filtering)
If this value is set to
, the set filters
tRue
are taken as default
values. This requires
a prior login with
admin rights.
Description
Returns the result of
the operation.