Processor unit
7
Startup and operation (continued)
Auto-Setup
Parameter-ID:
1003
hex
UHF-Manager:
Menu: Device settings > Parameters...
> Transmitting power
OPC UA:
Webserver:
Menu: Configuration > RFID > Anten-
nas & power
When the Auto-Setup parameter is set to the value 1, the
processor unit starts directly with the Auto-Setup via the
specified antenna. During the Auto-Setup, no further
commands are accepted by the processor unit, but the
value of the parameter can be queried cyclically to detect
the end and the result of the Auto-Setup.
The Auto-Setup is used to set the optimal transmitting
power in a single tag application. For this purpose, the
transmitting power is set so that only the data carrier
positioned in front of the antenna is detected and
processed.
During Auto-Setup, the RF LED (blue) indicates that the
UHF field is on.
To be able to start the Auto-Setup, at least the e
level is required.
Auto-Setup can and must be activated for each antenna
individually.
After successful completion, the Auto-Setup modifies both
the global parameters 0008
antenna read (default) and 0009
transmitting power on write and the session-related
parameter 1001
Transmitting power for antenna read
hex
(current).
60
english
user
xpeRt
Transmitting power for
hex
Automatic increase of
hex
Adjustable values:
Length
Permissi-
Factory
[bits]
ble values
setting
8
1
0 (Off)
Automati-
cally falls
back to 0,
2, 3 or 4
after com-
pletion
The value read back means the following:
0: Auto-Setup not yet started or successfully
completed. A single tag was able to be reliably read
and written to on its own based on the power. All
parameters were set.
1: Auto-Setup not yet completed.
2: Auto-Setup partially successful. Several tags were
able to be detected, the transmitting power 0008
and 1001
were set to be able to detect and read at
hex
least one tag reliably.
3: Auto-Setup failed completely. No tag was found or it
could not be read. No parameters were changed.
4: Auto-Setup partially successful. A single tag was
able to be read reliably on its own based on the power,
but not written to. The following reasons are possible:
– Tag does not contain user data.
– Tags are read-only.
– The maximum power of the device is not sufficient to
write reliably.
The transmitting power 0008
set to reliably detect and read this tag.
Meaning
1: Auto-Setup
0: Inactive
hex
and 1001
have been
hex
hex