Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS U-6127-081-1 4-06-ST36 Betriebsanleitung Seite 202

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-6127-081-1_4-06-ST36
Processor unit
6
Application planning (continued)
Loop filter in asynchronous mode
In asynchronous mode, the loop filter is active immediately.
An event for a new tag is triggered when the condition
Minimum number of successful reads is met. An event for
a tag that is no longer found is only triggered when the
Number of non-reads is exceeded.
Loop filter in synchronous mode
In synchronous mode, the loop filter can be used as
follows:
Live mode: Scans and filter operation are performed in
the background, query of the current data carrier list
(after filtering) via the normal synchronous commands.
The mode is suitable for continuously repeated queries
in short intervals.
Cumulative mode: Scans and filter operation take place
in the background, query of all newly found data
carriers (including those that have left the antenna read
field again in the meantime) via the normal synchronous
commands.
The mode is suitable for obtaining a complete list of
data carriers via triggered or occasional queries (e.g. in
a gate application).
In addition to the actual filter function, the combination of
the loop filter and synchronous operation has the following
advantages:
The responses to synchronous commands and
method calls occur almost without any waiting time,
since the actual data carrier search runs independently
of this in the background.
The application on the controlling device can determine
when it wants to fetch the results of the data carrier
search without the risk of losing results, as they can be
collected and cached (accumulated) in the device.
The loop filter can be used in synchronous mode as
follows:
26
english
Live mode
Command
007 protocol
Start data carrier
Set the parameter
detection with loop
1006
hex
filter, Live mode
value 1
Read data carrier
GetMultipleTags
list Live mode
command GetMul-
tipleTagsExtended
command
Read data carrier
UniversalTagList
list Live mode and
command
read any data,
user-defined output
Output the current
GetTagCount
number of tags in
command
the data carrier list
End data carrier
Abort command or
detection with loop
set parameter
filter
1006
hex
value 0.
The formatted output can only be used if only EPC data and status
1)
values are to be output, since data carriers may no longer be in the
read field of the antennas at the time of the query and further data may
then no longer be available and thus an output is then not carried out.
Cumulative mode
Command
007 protocol
Start data carrier
Set the parameter
detection with loop
1006
hex
filter, cumulative
value 9
mode
Read data carrier
GetMultipleTags
list Cumulative
command GetMul-
mode
tipleTagsExtended
command
Read data carrier
UniversalTagList
list Cumulative
command
mode and read any
data, user-defined
output
Output the current
GetTagCount
number of tags in
command
the data carrier list
End data carrier
Abort command or
detection with loop
set parameter
filter
1006
hex
value 0.
The formatted output can only be used if only EPC data and status
1)
values are to be output, since data carriers may no longer be in the
read field of the antennas at the time of the query and further data may
then no longer be available and thus an output is then not carried out.
OPC UA
ScanStart()
to the
method
Scan()
method
ReadMulti-
pleTagData-
1
Formatted()
method
1
Scan()
method
ScanStop()
method
to the
OPC UA
Not possi-
to the
ble
Not possi-
ble
Not possi-
ble
1
Scan()
method
ScanStop()
method
to the

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bis0193