Herunterladen Inhalt Inhalt Diese Seite drucken

Detect Data Carriers, Asynchronous - Balluff BIS U-6127-081-1 4-06-ST36 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-6127-081-1_4-06-ST36
Processor unit
8
007 protocol (continued)
Byte
Data (Hex)
04...53
00, 00, 00, 00, 00, 00,
00, 00, 00, 00, 00, 00,
00, 00, 00, 00, 00, 00,
00, 00, 00, 00, 00, 00,
00, 00, 00, 00, 00, 00,
00, 00, 00, 00, 00, 00,
00, 00, 00, 00, 00, 00,
00, 00, 00, 00, 00, 00,
00, 00
54...65
12, 11, 10, 09, 08, 07,
06, 05, 04, 03, 02, 01
66
30 00
68
00 00
70
00 00
72
32 32 34
75
31 34 33 32 32 36 34
35 30
84
04
85
33
86
3E
87
00
88...149 62, 00, 60, 00, 00, 00,
00, 55, 00, 00, 00, 00,
50, 00, 00, 00, 00, 45,
00, 00, 00, 00, 40, 00,
00, 00, 00, 35, 00, 00,
00, 00, 30, 00, 00, 00,
00, 25, 00, 00, 00, 00,
20, 00, 00, 00, 00, 15,
00, 00, 00, 00, 10, 00,
00, 00, 00, 05, 00, 00,
00, 01
150
F8 00
152
00 00
154
00 00
156
32 32 36
159
31 34 33 32 32 36 34
37 35
104
english
Description
8.9
Pad-Byte
Command identifier <DLE>: asynchronous Tag
comes/Tag goes message
The asynchronous messages t
used to monitor which data carriers are in the detection
range of the antennas and which are leaving it.
The asynchronous message t
carrier as present once as soon as it enters the detection
range of an antenna and the conditions of the filter
functions are met.
EPC:
The asynchronous message t
01 02 03 04 05 06
detected data carrier as absent once as soon as it leaves
07 08 09 10 11 12
the detection range of an antenna and the conditions of
PC word (EPC
the filter functions are fulfilled.
length 12 bytes)
XPC_w1
XPC_w2
RSSI (ASCII)
"224" = −32
Timestamp (ASCII)
14:32:26.450
Tag detected at
antenna 3
Highest RSSI at
antenna '3'
EPC has a length of
62 bytes
Reserved
EPC:
01, 00, 00, 00, 05,
00, 00, 00, 00, 10,
00, 00, 00, 00, 15,
00, 00, 00, 00, 20,
00, 00, 00, 00, 25,
00, 00, 00, 00, 30,
00, 00, 00, 00, 35,
00, 00, 00, 00, 40,
00, 00, 00, 00, 45,
00, 00, 00, 00, 50,
00, 00, 00, 00, 55,
00, 00, 00, 00, 60,
00, 62
PC word (EPC
length 62 bytes)
XPC_w1
XPC_w2
RSSI (ASCII)
"226" = −30
Time stamp (ASCII)
14:32:26.475

Detect data carriers, asynchronous

ag comeS
ag goeS
Asynchronous messages are sent only if the
asynchronous mode and the sending of messa-
ges has been enabled via the a
parameter (1006
), see chapter 7.3 on
hex
page 49.
Data carriers with the same EPC are treated as
a single data carrier.
Byte
Length
Command
element
00
1
Asynchronous
message
01
1
"Tag comes" or
"Tag goes"
message
02
1
Antenna number
(ASCII)
03
1
Identifier for EPC
data
04
1
Reserved
05...06 2
Number of bytes
ID (ASCII)
07
1
EPC length
08
1
Reserved
09...70 62
EPC (LSB...MSB) 00
70...73 4
Reserved
74
1
BCC
/t
can be
ag comeS
ag goeS
reports a data
reports an already
o
Sync
peRation
Value range
<DLE>
'+': Tag comes
'−': Tag goes
'0'
'E'
20
hex
"64"
02
...3E
hex
hex
00
hex
...FF
hex
hex
"0000"
00
...FF
hex
hex

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bis0193

Inhaltsverzeichnis