Processor unit
9
OPC UA (continued)
9.5.3
Methods for scan settings
SetAntennaUsed
This method can be used to select one or more antennas
to be active in this session.
Min. Access Level: User
Default values: Parameter 0012
page 49)
Input parameter
Name
Data Type
AntennaUsed
BalluffAntenn-
aUsed
Output parameter
Name
Data Type
Status
AutoIdOperati-
onStatusEnu-
meration (see
chapter 9.7.2 on
page 161)
GetAntennaUsed
The method provides information about which antennas
are active in the current session.
Output parameter
Name
Data Type
AntennaUsed
BalluffAntenn-
aUsed
Result
AutoIdOperati-
onStatusEnu-
meration (see
chapter 9.7.2 on
page 161)
148
english
(see chapter 7.3 on
hex
Description
Selection of anten-
nas to be used in
this session.
Description
Returns the result of
the operation.
Description
Indicates which
antennas are active
in this session.
Returns the result of
the operation.
SetAsynchFilter
This method can be used to set the loop filter for the
corresponding session. The filter can be used to correct
false readings and to combine multiple scans into one list
(see Loop filter on page 25).
Min. Access Level: Expert
Default values: Parameters 0023
(see chapter 7.3 on page 49)
Call parameter
Name
Data Type
NumberOfRead-
UInt16
sToDetectTag
NumberOfRead-
UInt16
sToRemoveTag
TimeBetween-
UInt16
RemoveAnd-
Detect
UseAsDefault
Boolean
Return parameter
Name
Data Type
Result
AutoIdOperati-
onStatusEnu-
meration (see
chapter 9.7.2
on page 161)
, 0024
and 0029
hex
hex
hex
Description
Specifies how many
times a tag must be
successfully read
before it is actually
reported as
detected.
Specifies how many
times a tag must be
no longer detected
before it is actually
reported as no
longer present.
The time between
tag no longer
detected and tag
detected again. This
means that at least
this time must
elapse before a tag
may be reported as
detected again.
If this value is set to
, the set filters
tRue
are taken as default
values.
Description
Returns the result of
the operation.