Processor unit
9
OPC UA (continued)
SetTagPassword
This method can be used to write the access and kill
passwords of the data carrier. The passwords have a
length of 4 bytes each (MSB first).
For the kill command (p.197), a kill password different from
0 must have been written on the tag beforehand.
Call parameter
Name
Data Type
Identifier
ScanData (see
chapter 9.7.14
on page 164)
CodeType
CodeTypeData-
Type (see
chapter 9.7.4
on page 162)
PasswordType
RfidPassword-
TypeEnumera-
tion (see chap-
ter 9.7.11 on
page 163)
AccessPass-
ByteString
word
NewPassword
ByteString
Return parameter
Name
Data Type
Status
AutoIdOperati-
onStatusEnu-
meration (see
chapter 9.7.2
on page 161)
www.balluff.com
SetTIDLength
This method can be used to set the length of the TID
memory area to be used for all data carriers of a particular
antenna. The method is session-related.
Min. Access Level: Expert
Default values: Parameter 0004
page 49)
Input parameter
Description
EPC of the tag.
Specifies the type
for the Identifier
parameter.
Specifies which
password is to be
changed.
The Read and Write
Output parameter
values are not
supported on UHF
devices such as the
BIS U.6127 because
they are not defined
in the UHF EPC
Gen2 V1 specifica-
tion.
The current 4 byte
GetTIDLength
access password of
the tag.
This method returns the selected length of the TID memory
area for all tags of a given antenna. The method is session-
The new 4-byte-long
related
password.
Input parameter
Description
Returns the result of
the operation.
Output parameter
Name
Data Type
Antenna
BalluffAntenna-
Enumeration
TIDLength
Byte
Name
Data Type
Result
AutoIdOperati-
onStatusEnu-
meration (see
chapter 9.7.2
on page 161)
Name
Data Type
Antenna
BalluffAntenna-
Enumeration
Name
Data Type
TIDLength
Byte
Result
AutoIdOperati-
onStatusEnu-
meration (see
chapter 9.7.2
on page 161)
(see chapter 7.3 on
hex
Description
Antenna where the
TID length should
apply to all tags.
Desired TID length in
2-byte words to be
set.
Maximum allowed
length: 31 words
(62 bytes)
Description
Returns the result of
the operation.
Description
Antenna for which
the set TID length is
to be returned.
Description
Length of the TID
memory area in
2-byte words.
Returns the result of
the operation.