Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS U-6127-081-1 4-06-ST36 Betriebsanleitung Seite 323

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-6127-081-1_4-06-ST36
Processor unit
9
OPC UA (continued)
LockTag
This method can be used to lock a specific memory area
of a tag for any access. Depending on the selection, this
setting may or may not be reversible.
Call parameter
Name
Data Type
Identifier
ScanData (see
chapter 9.7.14
on page 164)
CodeType
CodeTypeData-
Type (see chap-
ter 9.7.4 on
page 162)
Password
ByteString
Region
RfidLockRegio-
nEnumeration
(see chap-
ter 9.7.10 on
page 163)
Lock
RfidLockOpera-
tionEnumeration
(see chap-
ter 9.7.9 on
page 163)
Offset
UInt32
Length
UInt32
Return parameter
Name
Data Type
Status
AutoIdOperati-
onStatusEnu-
meration (see
chapter 9.7.2 on
page 161)
www.balluff.com
Description
EPC of the tag to be
locked.
Specifies the type
for the i
dentified
parameter.
4-byte-long pass-
word for the lock
command.
Memory area to be
locked.
Specification of how
the memory area is
to be locked.
Is ignored.
Is ignored.
Description
Returns the result of
the operation.
KillTag
This method permanently disables a specific tag and locks
it from any use. The deactivation cannot be undone.
To execute the kill command, a kill password must first be
set and written to the data carrier (SetTagPassword()
method, see page 155).
Call parameter
Name
Data Type
Identifier
ScanData (see
chapter 9.7.14
on page 164)
CodeType
CodeTypeData-
Type (see chap-
ter 9.7.4 on
page 162)
Password
ByteString
Return parameter
Name
Data Type
Status
AutoIdOperati-
onStatusEnu-
meration (see
chapter 9.7.2 on
page 161)
Description
EPC of the tag to be
disabled.
Specifies the type
for the i
dentified
parameter.
Password of the kill
operation.
Description
Returns the result of
the operation.
english
147

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bis0193