Processor unit
7
Startup and operation (continued)
MinReads or AsyncObserved-Threshold
Parameter-ID:
100C
hex
UHF-Manager:
OPC UA:
SetASyncFilter/GetASyncFilter methods
Webserver:
The MinReads parameter defines how often a data carrier
must be detected so that it is reported as c
parameter overwrites the MinReads (default) parameter
and is valid until the current TCP session is terminated or
the processor unit is restarted.
If a data carrier is to be detected twice in succession, for
example, before it is reported as c
the parameter value.
Adjustable values:
Length
Permissi-
Factory
[bits]
ble values
setting
8
1...255
1
MinNoReads or AsyncObserved-Timeout (default)
Parameter-ID:
0024
hex
UHF-Manager:
Menu: Device settings > Parameters...
> Read-Write
OPC UA:
SetASyncFilter/GetASyncFilter methods
Webserver:
Menu: Configuration > RFID > Filter
options
The MinNoReads (default) parameter specifies how often a
data carrier reported as Comes must not be detected for it
to be reported as g
. This value is set after switching on
oeS
or restarting the processor unit.
If, for example, a data carrier is only to be reported as g
if it has not been detected twice in succession, 2 must be
set as the parameter value.
Adjustable values:
Length
Permissi-
Factory
[bits]
ble values
setting
8
1...255
1
www.balluff.com
. This
omeS
, 2 must be set as
omeS
Meaning
Required
detections to
report a data
carrier as c
.
omeS
oeS
Meaning
Required
detection failures
to report a data
carrier as g
.
oeS
MinNoReads or AsyncObserved-Timeout
Parameter-ID:
100D
hex
UHF-Manager:
OPC UA:
SetASyncFilter/GetASyncFilter methods
Webserver:
The MinNoReads (default) parameter specifies how often a
data carrier reported as c
omeS
to be reported as g
. This parameter overwrites the
oeS
MinNoReads (default) parameter and is valid until the
current TCP session is terminated or the processor unit is
restarted.
If, for example, a data carrier is only to be reported as g
if it has not been detected twice in succession, 2 must be
set as the parameter value.
Adjustable values:
Length
Permissi-
Factory
[bits]
ble values
setting
8
1...255
1
WaitTime (default)
Parameter-ID:
0029
hex
UHF-Manager:
Menu: Device settings > Parameters...
> Read-Write
OPC UA:
SetASyncFilter/GetASyncFilter methods
Webserver:
Menu: Configuration > RFID > Filter
options
The WaitTime (default) parameter specifies the time interval
after which a data carrier reported as g
re-detected. This value is set after switching on or
restarting the processor unit.
The 16-bit value is coded in 2 bytes in the order
Low – High.
Adjustable values:
Length
Permissi-
Factory
[bits]
ble values
setting
16
0...1000
0
must not be detected for it
oeS
Meaning
Required
detection failures
to report a data
carrier as g
.
oeS
can be
oeS
Meaning
Time in
seconds
during which a
data carrier is
ignored.
english
63