BIS U-6127-081-1_4-06-ST36
Processor unit
7
Startup and operation (continued)
RSSIMinFilter
Parameter-ID:
1013
hex
UHF-Manager:
OPC UA:
SetFilter/GetFilter methods
Webserver:
RSSIMinFilter overwrites the RSSIMinFilter (default)
parameter and defines the RSSI lower limit to be used for
detection. The parameter is valid until the current TCP
session is terminated or the processor unit is restarted.
Adjustable values:
Length
Permissible
[byte]
values
1
−128...+127
RSSIMaxFilter (default)
Parameter-ID:
0030
hex
UHF-Manager:
Menu: Device settings > Parameters...
> Filter
OPC UA:
SetFilter/GetFilter methods
Webserver:
Menu: Configuration > RFID > Filter
options
RSSIMaxFilter (default) specifies the RSSI upper limit to be
used for detection. The defined value is used by the
processor unit after switching on or after restarting the
processor unit.
Adjustable values:
Length
Permissible
[byte]
values
1
−128...+127
68
english
Factory
Meaning
setting
−128
RSSI lower limit
for the RSSI
filter
Factory
Meaning
setting
+127
RSSI upper limit
for the RSSI
filter
RSSIMaxFilter
Parameter-ID:
1014
hex
UHF-Manager:
OPC UA:
SetFilter/GetFilter methods
Webserver:
RSSIMaxFilter overwrites the RSSIMaxFilter (default)
parameter and specifies the RSSI upper limit to be used
for detection. The parameter is valid until the current TCP
session is terminated or the processor unit is restarted.
Adjustable values:
Length
Permissible
Factory
[byte]
values
setting
1
−128...+127
+127
Meaning
RSSI upper limit
for the RSSI
filter