Processor unit
9
OPC UA (continued)
LastScanData
Data Type
ByteString
Default value
""
Access rights
Read: User
Write: –
007-Parameter
Parent
AutoIdDeviceType
Path
Root/DeviceSet/BIS_U_6127_Rfid_
Provider/
This variable returns the data of the last detected data
carrier. It is shared by all OPC UA sessions.
MinRSSI
Data Type
Int32
Default value
−128 (parameter 002f
Access rights
Read: User
Write: User
007-Parameter
Parent
AutoIdDeviceType/RuntimeParameters
Path
Root/DeviceSet/BIS_U_6127_Rfid_
Provider/RuntimeParametersGlobal/
BalluffRfidRuntimeParametersAn-
tenna[1..4]
Each tag at the corresponding antenna must be detected
with at least this RSSI value to be reported as detected. In
OPC UA, this value is reflected in the filters (see SetFilter
on page 150).
The RSSI (Received Signal Strength Indicator) is a value
that reflects the signal quality of a received data carrier
response. Conclusions can only be drawn to a limited
extent about the distance of the data carrier from the
antenna.
RFPower
Data Type
SByte
Default value
0
Access rights
Read: User
Write: Admin
007-Parameter
0x0008 / 4
Parent
AutoIdDeviceType/RuntimeParameters
Path
Root/DeviceSet/BIS_U_6127_Rfid_
Provider/RuntimeParametersGlobal/
BalluffRfidRuntimeParametersAn-
tenna[1..4]
This value specifies the transmitting power of the
corresponding antenna in dBm. Only integer values are
possible here. Finer settings can also be made via the web
interface or the UHF Manager. The transmitting power
influences the maximum range of the detection range of
the antenna.
160
english
TagTypes
Data Type
Default value
Access rights
007-Parameter
Parent
Path
This array returns the tag types supported by the system.
UserLed
)
hex
Data Type
Default value
Access rights
007-Parameter
Parent
Path
This variable can be used to control the LED of the device.
The following values are possible:
0: Led off
1: Led lights up red
2: Led lights up yellow
3: Led lights up green
UInt32[]
"EPC Class 1 Gen2 V1",
"ISO 18000-63"
Read: User
Write: –
AutoIdDeviceType/RuntimeParameters
Root/DeviceSet/BIS_U_6127_Rfid_
Provider/RuntimeParametersGlobal/
BalluffRfidRuntimeParametersAn-
tenna[1..4]
BalluffUserLedEnumeration
0 = off
Read: User
Write: User
Balluff extension: AutoIdDeviceType/
RuntimeParameters
Root/DeviceSet/BIS_U_6127_Rfid_
Provider/RuntimeParametersGlobal/
BalluffRfidRuntimeParametersCom-
mon