Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS U-6127-081-1 4-06-ST36 Betriebsanleitung Seite 307

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-6127-081-1_4-06-ST36
Processor unit
8
007 protocol (continued)
Command identifier 'X': Cyclical process data, write
Send process data via the IO-Link interface.
To be able to send data via the IO-Link inter-
face, the IO-Link port (pin 4) must be configured
as a data port (C/Q) (see Command identifier
'g': IO-Link master configuration, write on
page 129).
Byte
Length
Command
element
00
1
Command
identifier (ASCII)
01...03 3
Start address
(ASCII)
04...06 3
Number of bytes
(ASCII)
07
1
BCC
Status message:
Byte
Length
Command
element
00
1
Status
01
1
Status code
If the status message is positive, data can be transmitted
with <STX>.
Byte
Length
Command
element
00
1
Control com-
mand
01
No. of
Data
bytes
Last
1
BCC
byte
Status message:
Byte
Length
Command
element
00
1
Status
01
1
Status code
www.balluff.com
Value range
'X'
"000"..."999"
"000"..."999"
00
...FF
hex
hex
Value range
<ACK> or
<NAK>
See Status codes
on page 94
Value range
<STX>
Byte:
00
...FF
hex
hex
00
...FF
hex
hex
Value range
<ACK> or
<NAK>
See Status codes
on page 94
english
131

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bis0193

Inhaltsverzeichnis