Startup and operation
7.1

UHF Manager configuration software

The Balluff UHF Manager configuration software provides
an easy way to start up the RFID system, test basic
functions and make parameter settings before installation.
7.1.1

Install and start configuration software

The configuration software is available online at
www.balluff.com.
Administrator rights may be required to install
the software. The software is installed under the
preset path (unless it is changed):
C:\Program Files (x86)\Balluff\UHF
Manager
1. Start the installation wizard by double-clicking the
installation file (UhfManagerSetup_version.msi) and
follow the wizard instructions.
2. Double-click on the Balluff.Uhf.UhfManager.exe file in
the installation directory to start the configuration
software.
7.1.2

User interface

After connecting the processor unit via TCP/IP or USB (see
chapter 7.1.3 on page 30), the main window is
displayed as follows (see Fig. 7-1).
Fig. 7-1:
Main window
RFID system information
The left window area displays the RFID system information
for a connected BIS processor unit. This shows a
schematic representation of the processor unit and
provides information about the following:
Type designation of the connected processor unit
Firmware version of the processor unit
Connection status of the interface used
Currently selected antenna via the radio buttons 1...4
or a
ll
www.balluff.com
Action area
The action area in the center of the window shows the
data of the data carriers found in the active field of the
antenna and provides the controls necessary to interact
with a data carrier.
Status bar
The status bar below the action area shows the result of
the last executed action.
Information on the operation of the UHF Mana-
ger is provided by the help function. This can be
called up via the Help menu or by pressing the
F1 key.
Menu
Fig. 7-2:
Menu display
Login/Logout
The BIS U-6127 processor unit has password-protected
security levels that allow different user groups to make
more detailed settings on the device. The u
a
levels can be activated or deactivated via l
dmin
l
. Higher security levels can perform additional
ogout
settings in the d
evice SettingS
Users are automatically logged out of the system after a
period of inactivity of 15 minutes and a new login is
required. A new login must be performed after 24 hours at
the latest.
Login (on delivery):
Security
Username
level
User
w/o
Admin
admin_default
(default)
User roles and login data can be managed via
user accounts (see User accounts on
page 11 and User Management on
page 45).
We recommend creating the following user roles:
Security
Username
level
Expert
expert
Administrator admin
/e
/
SeR
xpeRt
/
ogin
menu item.
Password
w/o
See type plate on the
device
Password
Freely definable
Freely definable
english
29