Processor unit
8
007 protocol (continued)
8.5

Command overview

General commands
Function
Command
recognition
ASCII
Abort
'Q'
System
'q'
Reboot
Read network
'm'
parameters
Change
'j'
network
parameters
Read trans-
'o'
mitting power
Change
'p'
transmitting
power
Read device
'G'
parameters
Change
'E'
device para-
meters
Read version
'V'
www.balluff.com
Description
HEX
51
Abort asynchro-
hex
nous commands.
71
System reboot
hex
6D
Read Ethernet
hex
network parame-
ters.
6A
Set Ethernet
hex
network parame-
ters.
6F
Read out transmit-
hex
ting power of
specified antenna.
70
Set transmitting
hex
power of specified
antenna.
47
Read out device
hex
parameters.
45
Set device para-
hex
meters.
56
Read out informa-
hex
tion on processor
unit.
BIS U type
designation
Hardware
version/
firmware
version/serial
number
IO-Link FW
version
Detect data carriers
Function
Command
recognition
ASCII
Number of
'N'
data carriers
Detect data
'M'
carriers
Detect data
','
carriers,
extended
Asynchronous messages, Tag goes/Tag comes
Function
Command
recognition
ASCII
Data carrier
<DLE>
102B
comes, event
'+'
Data carrier
<DLE>
102D
goes, event
'−'
Description
HEX
4E
Query the number
hex
of tags that are
within the detec-
tion range of the
specified antenna.
4D
Detects the data
hex
carriers that are in
the detection range
of the specified
antenna and
returns a list of the
requested data
(EPC or TID).
2C
Detects the data
hex
carriers that are in
the detection range
of the specified
antenna and
returns a list of the
requested data
(EPC or TID) and
additional informa-
tion.
Description
HEX
Reports a tag as
hex
Comes when it
enters the detec-
tion range.
Reports a tag as
hex
Goes when it
leaves the detec-
tion range.
english