Electrical connections, LEDs
Phase delays of group 4
Fieldbus
EtherCAT /
PROFINET
EtherNet/IP™ /
PROFIBUS
Modbus TCP
Example 5
Signal delay from the input (group 1) with a Bessel filter with 1 kHz to the field-
bus master (group 4).
A/D converter (ADC) plus filter: 690 μs.
Added to this is a jitter of up to 52 μs, as the A/D converter is not synchro-
nized with group 1. Group 1: 690 μs + 52 μs max.
Fieldbus output with EtherCAT or PROFINET (4 kHz frame rate): max.
370 μs + 250 μs + 250 μs (typ. 250 μs + 125 μs + 250 μs = 625 μs).
So the total phase delay is between 1.315 ms (min.) and 1.612 ms (max.).
68
Data transfer in
ms
0.25
1
1
A04643_04_X00_03 HBM: public
Phase delay typ.
in ms
0.25 + frame rate/2
0.65 + frame rate/2
Phase delay
max. in ms
0,37 + frame rate
1,1 + frame rate
ClipX