Herunterladen Inhalt Inhalt Diese Seite drucken

HBM ClipX Bedienungsanleitung Seite 35

Vorschau ausblenden Andere Handbücher für ClipX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NS
Status
LED
Flashing
(1 Hz)
red
On
PROFIBUS LED (BUS, only BM40PB)
LED
Status
BUS
Off
off
Flashing
cyclically
(2 Hz)
green
On
Flashing
briefly (1 Hz)
Flashing
cyclically
red
(2 Hz)
On
ClipX
Meaning
Connection timeout.
One or more connections to this ClipX are in timeout. This
status will only be terminated when all connections have
been restored or you reset the ClipX.
Duplicate IP address.
The ClipX has detected that the IP address assigned to it
(and set) is already being used in the network.
Meaning
The ClipX is not on, or the network has no power.
The master is in the CLEAR state.
The ClipX is in the RUN state; cyclic communication is run-
ning.
The ClipX is not configured.
The ClipX is in the STOP state.
No communication; a connection error has possibly
occurred.
Incorrect PROFIBUS-DP configuration.
A04643_04_X00_03 HBM: public