Operation via fieldbus
Subin-
Index
dex
0x4270
3
4
5
6
11
0x4271
1 ... 10
50
178
Function
Save current parameters
from the RAM permanently
under this parameter set
number (overwrite existing
parameter set).
Define start parameter set
number (permanently
stored in the system param-
eters).
Mode for switching parame-
ter set via the debounced
digital inputs.
Reset current parameters in
the RAM to their factory
does not
defaults (but this
save the parameters per-
manently).
Flag indicating whether a
parameter in the parameter
set has been changed in the
current settings.
Name of the parameter set
in question.
Current parameter set
name.
You save the parameter set
under this name with com-
mand 0x4270.3.
A04643_04_X00_03 HBM: public
Value
1 ... 10, INT16, WO.
1 ... 10, UINT16.
0: Deactivated
1: Use only digital input 1
2: Use digital inputs 1 and 2,
UINT8.
WO.
0: Not changed
1: Changed, UINT8.
STRING, RO.
STRING.