Herunterladen Inhalt Inhalt Diese Seite drucken

HBM ClipX Bedienungsanleitung Seite 105

Vorschau ausblenden Andere Handbücher für ClipX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Starting up the ClipX
In the case of single shot and Start on: Low level, a negative edge starts the
timer and the next negative edge only restarts the timer when the time has
elapsed. In continuous mode, the timer starts as soon as a low level (0) is on
Start/Stop with, and immediately restarts at the end of the interval. As soon as
no low level is active any more, the timer is stopped and is only restarted when
a low level is received.
Both the Timer Flag and the current time value (Time) are outputted: 0 when
the timer starts, the Interval value at the end of the interval. When the timer is
stopped, the interval time is outputted constantly.
7.4.2.16 Standstill detection
The calculation checks two states:
1. Whether the signal amplitude within a certain period of time is smaller than
the specified value.
2. Whether the signal is near zero (within defined limits).
If both the Standstill Flag and the Near Zero Flag are set, the Output is set to
0.
Standstill detection
Specify the Time within which the Amplitude must be less than indicated. If this
condition is met, the Standstill Flag is set.
Near zero detection
Specify a positive value for Threshold High and a negative value (with sign) for
Threshold Low. Positive values for the low threshold or negative values for the
high threshold are not allowed. As soon as the source signal is within these lim-
its, the Near Zero Flag is set.
ClipX
103
A04643_04_X00_03 HBM: public

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis