Operation via fieldbus
Subin-
Index
dex
0x6323
1
0x6330
1
9.7.9
List of signal references
If you want to specify a signal as a subindex in the object dictionary
(see
"Measuring channel objects" on page
add 1 to the values in this list. Enter 4 for the gross signal and 5 for
the net signal for example.
Designation
Electrical value (field
value)
Gross
Net
Minimum
Maximum
Peak-to-peak
Captured value 1
Captured value 2
222
Function
Analog output scaling 2 field
value.
Analog output field value
(read only).
Value
Explanation
Input signal in the unit of the measured variable, e.g.
2
in mV/V.
3
Gross signal.
4
Net signal.
5
Peak value Minimum.
6
Peak value Maximum.
7
Peak-to-peak value.
8
Captured value 1.
9
Captured value 2.
A04643_04_X00_03 HBM: public
Value
Physical value for the analog
output in the unit V or mA,
FLOAT.
Analog output in V or mA.
You cannot change the output
value directly. Output a value
via the test signal – see
0x4500.10: Analog output test
value and 0x4500.11: Analog
output test value active, FLOAT,
RO.