At the Operator and Maintenance user levels, only the Home and Visualiza-
tion menus are accessible by default. At the Administrator user level all setting
menus are accessible.
If no input is made at the Maintenance or Administrator user level,
the user level is reset to Operator after 30 minutes. The user level is
also reset when you close your browser and reconnect.
Forgotten your password?
You can temporarily disable user management by pressing and hold-
ing down the Reset button on the front of the ClipX while logging in or
changing a password (any password is accepted, including a blank
password field). You will normally need a second colleague to press
the button while you are logging in.
See also
Setting passwords and rights
Log in to the Administrator or Maintenance user level and use Change Pass-
word: Select User Level to choose the user level for which you want to set the
password. The length of the password is not actually limited, but it might be that
only a specific number of entered characters can be displayed depending on the
window size. All characters are allowed, including special characters. For secu-
rity reasons, you must enter the password twice before you can activate it with
CHANGE
PASSWORD.
Specify the menu items to be accessible at the Administrator user level at the
Maintenance level by checking the relevant checkboxes. At the Operator user
level no changes can be made; only the Home and Visualization menu items
can be displayed.
You can reset both passwords by loading the factory default setting in
the Device menu (Without network settings is sufficient).
ClipX
"Available connections and LEDs" on page
A04643_04_X00_03 HBM: public
Starting up the ClipX
24.
83