Electrical connections, LEDs
EtherCAT LEDs (RUN, ERR, only BM40IE)
RUN
Status
LED
Off
off
Flashing at
2.5 Hz
Single flash
green
On
ERR
Status
LED
Off
off
Flashing at
2.5 Hz
Single flash
Red
Double flash
30
Meaning
The ClipX is in the INIT state.
The ClipX is in the PRE-OPERATIONAL state.
The ClipX is in the SAFE-OPERATIONAL state.
The ClipX is in the OPERATIONAL state.
Meaning
No error.
The EtherCAT communication is running and error-free.
Invalid configuration.
Possible cause: A change specified by the master is not
possible.
Local error: The ClipX has autonomously changed the Eth-
erCAT status.
Possible causes:
– A host watchdog timeout has occurred,
– synchronization error. In this case the device switches
automatically to the SAFE-OPERATIONAL state.
A process data watchdog timeout has occurred.
Possible cause: A synchronization timeout (Sync Manager
watchdog).
A04643_04_X00_03 HBM: public