tion
Reply when
reading from
the object
dictionary
Reply when
writing to the
object dictio-
nary
1)
The time is dependent on the update rate of the source signal.
The following table shows the bit assignment of the object value (value field)
when accessing the object dictionary.
Bit 31 ... 24
ClipX
Cycle in
Format
ms
UINT
(Index)
USINT
(Subin-
dex)
USINT
1
(Error)
UDINT
(Value)
UINT
(Index)
USINT
(Subin-
1
dex)
USINT
(Error)
Bit 23 ... 16
Data object types UDINT, DINT, REAL, FLOAT
Not used
Not used
A04643_04_X00_03 HBM: public
Explanation
Reply to the read request: The value is valid
if Index and Subindex are identical to the
request and the error byte is zero.
Value of the reply. The value type is defined
as UDINT, but REAL values (FLOAT) are
also returned. To do so, copy the value with-
out a type conversion (cast operation) from
value! The table below explains the bit
assignment.
Reply to the write request: The object has
been successfully written to if Index and
Subindex are identical to the request and the
error byte is zero.
Bit 15 ... 8
Data object types INT, UINT
Operation via fieldbus
Bit 7 ... 0
Data object types