Standstill detection (block type 19), available with firmware 2.6 or higher
Subin-
Index
dex
0x510n
20
21
22
23
24
30
31
32
ClipX
Function
Input.
Time.
Amplitude.
High level.
Low level.
Standstill flag.
Near zero flag.
Output.
A04643_04_X00_03 HBM: public
Operation via fieldbus
Value
0 ... 47, see
"List of signal ref-
erences" on page
0 ... 60.000, time period in ms
within which the signal fluctu-
ations must be smaller than
the amplitude, UINT16.
> 0.0, FLOAT.
≥ 0.0, maximum permissible
positive value at which the
near-zero condition is still met,
FLOAT.
≤ 0.0, maximum permissible
negative value at which the
near-zero condition is still met,
FLOAT. The value must be
entered with a minus sign.
Flag number 12 ... 19, 64, see
"Digital flags: List of I/O flags
(I/O status)" on page
UINT8.
Flag number 12 ... 19, 64, see
"Digital flags: List of I/O flags
(I/O status)" on page
UINT8.
21 ... 26, 48, see
references" on page
UINT16.
222, UINT16.
162,
162,
"List of signal
222,
215