Herunterladen Inhalt Inhalt Diese Seite drucken

Signal Generator - HBM ClipX Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ClipX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Starting up the ClipX
Set Point
+
-
Process
Value
Fig. 48: Block diagram of the PID controller
You cannot define the PID controller as a simple P controller. At least
one I element must be present in addition (T
If either the target value or actual value is invalid, the controller stops and the
value is marked as invalid. However the output retains the last value. In the case
of Enable by: 0 the controller is reset and the value of Y
input has priority over the Start/Stop with signal.

7.4.2.13 Signal generator

This calculation generates a periodic signal, for example a sine wave. Deter-
mine the desired frequency, amplitude and, if applicable, an offset. Signal forms
available are sine, square wave, triangle, counter, constant and (white) noise.
The signal on Start/Stop with together with Start on determines whether the
selected function will be outputted. When Start on: High level) is set, on a Low
level (0) the output is stopped and the Offset value is outputted. When the sig-
nal switches back to High (1), a new output period begins.
Use 100 Hz (1/10 of the update rate) as the maximum frequency, other-
wise the output signal will not be formed from enough points. This results
in a distorted curve shape (stairway effect) for a sine wave.
100
K
G(s) =
p
G(s) =
A04643_04_X00_03 HBM: public
G(s) = 1
1
+
T
*s
+
i
T
*s
d
T
*s + 1
d
≥ 0.01 s).
i
+
Regulating
Variable
is outputted. This
Default
ClipX

Quicklinks ausblenden: