Electrical connections, LEDs
Pt100 (template: Resistive Temperature Detector)
Two-point scaling (always included in the respective sensor template)
Polynomial scaling (template: Calibration Curve)
HBM Channel Name (max. 45 ASCII characters)
HBM Unit Conversion (1 conversion factor and new unit)
HBM User Defined ID (max. 15 ASCII characters, e.g. for an identifier)
Restrictions
Only 1 segment with a maximum 4th order is supported for polynomial scal-
ing (Calibration Curve). Only "Electrical" is supported as "Domain parameter
of the Calibration Curve", meaning electrical values are converted to physi-
cal values. Correction of physical values to other physical values is not sup-
ported.
For Pt100 (Resistive Temperature Detector) measurements are always in
°C; the HBM Unit Conversion template cannot be used. However, you can
set a different unit via your web browser's Amplifier menu. Any conversion
template in the TEDS is not evaluated.
Read data from TEDS module or overwrite TEDS module
Requirements
A sensor with a TEDS module must be connected.
The setting for use of TEDS must be TEDS required or Use TEDS if avail-
able.
The ClipX must have firmware version 2.02 as a minimum.
Read out TEDS module
1. In your browser choose the TEDS menu.
2. Click in the Info area on
The data in the TEDS module is then read out. Depending on your browser set-
ting, you are prompted to select a folder, or the file is saved to your Download
folder. The file name is automatically generated according to the syntax
"IEEE1451_4_ManufacturerCode_ModelNumber_VersionLetter_Version-
52
WRITE TEDS DATA INTO
A04643_04_X00_03 HBM: public
FILE.