Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Analog Output - HBM ClipX Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ClipX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.9

Connecting the analog output

You can output voltage (±10 V) or current (4 ... 20 mA). The analog output is short-cir-
cuit-proof, the bandwidth is 3.8 kHz, the update rate is 19.2 kHz.
See also
„Available connections and LEDs" on page
Abb. 31: Plug terminal X3, pin assignment for analog output
Start-up behavior
On starting up the ClipX (power on), the analog output initially has a high output resis-
tance. After initializing, the status of the settings is determined in the Start parameter
set.
The factory default setting is: Output deactivated, gross signal as input (source), zero
value 0 V, scaling 0/0 and 5/5, value in case of "invalid" signal 0 V and test signal 0 V
(both inactive).
Value in case of error
Which value is outputted depends on whether you activate the value in case of an
"invalid" signal or not. Make the setting via the ClipX web server in your browser.
1.
Value in case of "invalid" signal active (switch in browser on the right and red)
If the input signal becomes invalid, or the output signal would be outside the range
of ±11 V or less than 3 mA or greater than 21 mA, the specified value is outputted.
2.
Value in case of "invalid" signal not active (switch in browser on the left and gray)
The highest or lowest possible value is outputted depending on the signal (±11 V, or
3 mA or 21 mA).
54
AO
Analog Out +
AO Analog Out ‒
Cable shield
24.
Electrical connections, LEDs
ClipX

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis