Enabling fixed ClipX Ethernet address 192.168.0.234 (from firmware 2.0)
1.
Switch on the supply voltage.
2.
Wait about one minute until the device is ready.
3.
Press the Reset button (see illustration) three times using a pen or small screw-
driver. Each press must be held for at least 0.5 seconds, and the pause between
them must not be more than 3 seconds.
4.
If the ClipX has successfully detected the button presses, the system LED flickers
yellow and the ClipX reboots. The fixed IP address is then set.
Otherwise, you have up to three minutes in which to repeat the sequence.
5.
Wait for the reboot to complete before connecting to the device.
>0.5s
Abb. 42: Sequence of button presses for the fixed IP address 192.168.0.234
Ethernet port settings afterwards
Fixed IP address (do not use DHCP).
IP address: 192.168.0.234.
Subnet mask: 255.255.255.0.
Device name: ClipX.
All gateway or DNS settings are cleared.
Your PC must be using an address from the range 192.168.0.1 to
192.168.0.233 or 192.168.0.235 to 192.168.0.254 for a connection to be
made.