Herunterladen Inhalt Inhalt Diese Seite drucken

HBM ClipX Bedienungsanleitung Seite 189

Vorschau ausblenden Andere Handbücher für ClipX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Index
Subindex
0x4300
19
20
21
22
23
52
53
74
ClipX
Operation via fieldbus
Function
Calibration Period (Days).
Calibration Date.
Calibration Initials.
HBM User Defined ID.
HBM Channel Name.
Command "Read sensor ID
of TEDS module".
Sensor ID of TEDS module;
populated automatically
after command 0x4300.4 or
0x4300.52.
Command: "Write file to
TEDS module" (from device
storage) and, if possible,
apply it. The existing TEDS
content is overwritten with
no confirmation prompt.
The setting for use of TEDS
must be "TEDS required" or
"Use TEDS if available".
Value
Calibration period in days,
UINT32, RO.
Calibration date, STRING, RO.
Calibration initials, STRING, RO.
User defined ID, max. 15 ASCII
characters, STRING, RO.
Channel name, max. 45 ASCII
characters, STRING, RO.
WO.
STRING with 8 bytes in hex, RO.
Filename, max. 33 characters
without extension or 37 char-
acters including extension. The
file extension .ted does not
have to be specified, STRING,
WO.