Digital outputs
CxA
CxB
Sync
DI2
DI1
DO2
DO1
0V
24V
Abb. 30: Plug terminal X2, pin assignment of digital outputs
Start-up behavior of the digital outputs
On starting up the ClipX (power on), each output initially has a high output resistance.
After initializing, the status of the settings is determined in the Start parameter set.
When an output is active, the supply voltage (10 ... 30 V) is switched through to it.
The factory default setting is: Output deactivated.
ClipX
Electrical connections, LEDs
Housing, cable shield optional
ClipX bus
X
ClipX bus GND
ClipX bus
Synchronization
DI
Digital In GND
Digital In 2
Digital In 1
Digital Out 2
Digital Out 1
Supply 0 V and Digital Out GND
Supply 10 ... 30 V