Fieldbus
Index
Subindex
0x4800
1
ClipX bus
See also
„I/O objects" on page
Index
Subindex
0x4429
1
OPC UA
Index
Subindex
0x4D00
1
0x4D00
2
0x4D00
3
174
Function
Fieldbus protocol type.
188.
Function
Reads all 6 ClipX bus val-
ues. All values originate
from the same bus cycle,
meaning there is little jitter
between the values. As all
the values come in one
response, less network
traffic is necessary.
Function
Endpoint URL with IP
address as a copy tem-
plate for the OPC-UA-Cli-
ent.
Endpoint URL with host-
name as a copy template
for the OPC-UA-Client.
Switch OPC UA on or off.
The value is stored.
Value
0: Fieldbus off
1: PROFIBUS
2: PROFINET
3: EtherCAT
4: EtherNet/IP™INT16
Value
6 floating-comma values, sep-
arated by ; (semicolon),
STRING, RO.
An invalid measured value is
always replaced by 1.001 *
30
10
; any defined substitute
value is not used here.
Value
e.g.
opc.tcp://172.19.192.10
0:4840 or hbk/clipx.
e.g.
opc.tcp://clipx:4840/hb
k/clipx.
0: OPC UA off
1: OPC UA on