Index
Subindex
0x4428
5
0x4428
6
0x4428
7
0x4428
8
0x4428
9
0x4428
20
178
Function
Indication for which FIFO
channel the specifications
in subindex 6 and 7 are to
apply.
Minimum difference value
for FIFO channel 1 ... 6 (with
difference trigger). This dif-
ference between the last
value stored in the FIFO and
the current value must be
exceeded in order to add an
entry for all 6 signal
sources. You must set all 6
difference values >0 so that
the difference trigger
becomes active.
Selection of the signal
source for FIFO channel 1 ...
6
Number of values per sec-
ond (recording rate) that
are to be stored during con-
tinuous filling or checked
for conditions (digital flags
or difference values).
Time of recording the first
value in the FIFO according
to the ClipX date/time.
Command: Read a FIFO
entry from all 6 FIFO chan-
nels and buffer it for subse-
quent reading (subindex 21
... 27). The entry is deleted
after this command.
Value
1 ... 6, UINT8.
<0: Difference trigger deacti-
vated
>0: Difference value, FLOAT.
0 ... 31, see
„List of signal refer-
ences" on page
218, UINT8.
0.1 ... 1000.0, FLOAT.
Date and time, e.g. "17.08.18
14:00:37", STRING, RO.
If there are no values in the
FIFO, subindex 21 ... 27 is used
for the measured values 1.001
30
* 10
and 0xffffffff for the time;
RO.