6.5
Connecting the supply voltage
Connect the supply voltage from 10 to 30 V
See also
„Available connections and LEDs" on page
Notice
Voltages above 30 V
Make sure that the supply voltage is between 10 and 30 V
CxA
CxB
Sync
DI2
DI1
DO2
DO1
0V
24V
Abb. 14: Supply voltage at plug terminal X2
For each ClipX you must provide a power output of 5 W plus the power required for ana-
log and digital outputs. Use an appropriately dimensioned cable for the supply voltage
to avoid an excessive voltage drop when operating multiple devices. We recommend
using wire end ferrules and a cable cross-section of 1.5 mm
34
can destroy the ClipX.
DC
Housing
ClipX bus
X
ClipX bus GND
ClipX bus
Synchronization
DI
Digital In GND
Digital In 2
Digital In 1
Digital Out 2
Digital Out 1
Supply 0 V
Supply 10 ... 30 V
to terminal X2 (top).
DC
24.
DC
2
.
(AWG16).
Electrical connections, LEDs
ClipX