Data transfer from the controller to the ClipX

See also
„Data types used by the ClipX" on page
The following table sets out the data and the speed at which the data are downloaded
by the ClipX in the event of a change. The speed (cycle in ms) is not synchronized with
the fieldbus, or with PROFINET IRT or EtherCAT Distributed Clocks. The inputs and out-
puts of the ClipX are processed out of sync with the fieldbus. The synchronous modes
of the ClipX with these fieldbus systems provide only synchronized data transfer, not
processing of the data. The processing of queries and commands, such as the control
word or access to the object dictionary, normally takes additional time. In case of doubt,
perform your own time measurements with your system – see also
delays within the ClipX and over the ClipX bus" on page
Name
Fieldbus
FLOAT
value 1
Fieldbus
value 2
Limit value 1
FLOAT
Limit value 2
Limit value 3
Limit value 4
122
Description
32 bits, integer unsigned
Text
Cycle in
Format
ms
1
1
121.
59.
Function
The ClipX uses these values like measure-
ment values, for example in calculated chan-
nels or for the limit switches.
You can assign these values physical units
for display in your browser.
The values have no status information, and
so are always classed by ClipX as valid.
Threshold values of the limit switches.
The ClipX reacts to changes, then the values
are applied. They are also applied when any
other value in the data changes from the con-
troller to the ClipX.
„Signal phase
ClipX
Operation via fieldbus