System LED (SYS)
SYS
Status
LED
Off
off
On
green
On
yellow
/
Flashing
red/
green
ClipX
Electrical connections, LEDs
Meaning
No supply voltage, or ClipX defective.
The ClipX has fully booted up, and is ready.
Error in PPMP connection (if activated) or
Error on ClipX bus:
– One or more of the expected devices is not transmit-
ting, or not responding
– Errors in data transfer
If an invalid external measured value is correctly transmit-
ted, it does NOT result in a yellow or red system LED. It
causes an invalid status of the external measured value in
question (one bit per value).
Manual device detection (via the browser) has been
started.
or
The ClipX is not ready.
or
None of the other meanings in this table applies. If this
state lasts longer than a few seconds, please contact HBM
- see
„Technical support" on page
Note that the red/green flash can also be triggered via your
browser to identify a device (Home menu, click on
231.
).